Gypsum floor underlayments provide noise control and much more.
Today,
when constructing multi-level buildings, poured floor underlayments are
selected for four major reasons: 1) to provide a level surface for the finished
floor, 2) to add fire resistance to the floor construction, 3) to add sound
control between floors of the building, and 4) to add thermal mass to the floor
(e.g. when used with a radiant floor heating system).
According to the International Building Code, ceiling/floor assemblies in
multi-level residential units must be built to achieve sound ratings of STC50
and IIC50. Sound Transmission Class tells how well the assembly blocks airborne
sound from passing through it. Impact Isolation Class tells how well the
assembly prevents impacts on the floor above (such as from the patter of little
feet) from causing noise in the room below. Designers can meet this requirement
by either using an assembly that a manufacturer has already tested in a lab or
by testing the actual assembly in the building after it has been
constructed.
To achieve a high IIC rating, a floor/ceiling assembly must be heavy enough to
resist acting like a trampoline when someone jumps up and down on it.
Typically, this is a concern with subfloor-on-joist construction. In addition,
the upper layer of the floor/ceiling assembly must be cushioned enough to
prevent vibrations from traveling through the structure when someone tap dances
on it. This is typically a concern for concrete slab
construction.
The easiest way to deaden tap dancing noise is to install carpet on the floor.
In fact, be careful when comparing IIC test data to make sure that a big jump
in IIC rating is not due mainly to the use of carpet. A concrete slab floor
with a carpet finish is an easy way to achieve high IIC
ratings.
Trampoline noise in subfloor-on-joist construction is reduced by adding a thick
layer of poured underlayment onto the prepared subfloor. This adds the weight
needed to reduce the trampoline noise but makes the floor surface hard so that
we now have tap dancing noise problems. Just as with the concrete slab
construction, the easiest way to solve this is with a carpet finish.
Since designers, architects and residents of multi-story buildings prefer a
variety of hard floor finishes, the necessary cushion layer can no longer be
placed on top, and we must achieve the same effect with the cushion located
between the subfloor and the underlayment.
Hacker Industries’ gypsum concrete floor underlayments, acoustical control
products, and self-leveling underlayments are widely used across North America
for sound resistance and fire ratings. These underlayments are a lightweight,
high-strength, non-structural cementious underlayment for use in a variety of
applications, from the historic Book Cadillac building in Detroit where its
Firm-Fill 3310 was used to renovate and restore existing concrete floors to the
Bard’s Crossing Retirement Home where Hacker Sound Mat II were utilized to
create a quieter environment.
The improved flowability and quick installation time make them an ideal choice
to level existing concrete subfloors in commercial and renovation projects.
Additionally, they are widely used for capping hydronic heat tubes to provide a
thermal mass for even heat distribution in the fast-growing radiant heating
market.
JM:
How is the system installed?
Hacker: Floor underlayments are installed by licensed applicators that are
trained to adhere to Quality Assurance Standards, which include compressive
strength testing, field quality audits, technical updates and continuing
education seminars.
Underlayments are delivered to the job site in bags and mixed with washed
masonry or plaster sand, tested in accordance with ASTM E11, and water in
approved mixing and pumping equipment with a water meter. Licensed Applicators
then pump the slurry into place over a structurally sound, L/360, subfloor and
screeded to create a flat, durable surface ready for the installation of
finished floor coverings.
As part of Hacker’s Quality Assurance Standards, applicators conduct “slump” or
patty-size tests to measure the design mix and product flow. Patty-size results
should be as recommended by product specifications. Additionally, field cube
samples of underlayments are taken using split brass molds and tested in
accordance with ASTM C 472 to test for compressive strengths. Patty-sized tests
are recommended to be performed every 10,000 square feet and cube samples taken
on each project.
For applications utilizing Hacker Sound Mat II, a perimeter isolation strip is
installed throughout the perimeter of the rooms to reduce the flanking paths
then the product is rolled onto a smooth surface. The seams are then sealed
with an approved tape. The applicator then pours a minimum of 1 inch of an
underlayment on top of the mat.
JM: What added value does your company bring to projects?
Hacker: The company supplies consistent tested products to trained and licensed
applicators. We train licensed applicators on job sites and in classroom
sessions. To educate the building community, several programs are offered, as
well as a CEU approved program that we supply to architects, builders and
general contractors through AIA approved lunch-and-learn programs.
The company supplies Quality Control Kits to general contractors enabling them
to conduct their own on-site patty test to ensure an accurate design mix.
Floor underlayments undergo third party testing to ensure that they meet
building standards for fire resistance, sound resistance and durability.
Hacker’s technical department is available to help contractors, architects and
builders choose the right underlayment.
Vice President Kerry Hacker is the technical contact for ASTM Standard F2419;
Standard Practice for the Installation of Thick Poured Gypsum Concrete Floor
Underlayments and the Preparation of the Surface to Receive Resilient Floor
Coverings. She is available to answer questions.
JM:
Do you have a published listing of floor/ceiling constructions that have been
tested?
Hacker: Hacker floor underlayments are listed in 85 UL floor/ceiling
assemblies. These 85 UL listings detail floor/ceiling assemblies utilizing a
Hacker Floor Underlayment as an integral component to achieve a 1, 2, 3, or
4-hour fire rating. By including our products in more listings, the
architectural and construction communities are provided the ability to specify
floor underlayments on a wider array of floor/ceiling
assemblies.
JM: Do you have recommended construction requirements for fire ratings, sound
control or LEED ratings?
Hacker: While architects and acoustical engineers specify project requirements,
there are a range of floor underlayments designed to meet project
specifications. The company’s floor underlayments have been comprehensively
tested for fire resistance and are listed in UL for applications requiring 1 to
4 hour fire ratings.
Regarding sound control, floor underlayments play an integral role in reducing
sound transmission. Again, the end user makes the decision as to the extent of
sound control desired. For optimum sound performance, the use of an acoustical
control mat is recommended in conjunction with a gypsum concrete floor
underlayment. Since minimizing sound control consists of many variables, the
goal is to provide components of a cost-effective system, which create a
quieter living environment.
To assist projects in obtaining LEED credits, the company’s gypsum concrete
floor underlayments and sound mat now contribute to sustainable, green building
sites. They contain recycled material and are available from most plants
throughout the U.S.
to help impact LEED credit areas.
As building codes have changed regarding noise control, the need for
fire-rated, green building products, which contribute to “soundproofing” the
buildings we live and work in, continues to grow. Gypsum concrete floor
underlayments and sound control mats are increasingly recognized by architects,
specifiers and builders as the solution to these flooring requirements. W&C
Sound Proof